Dear Ladies and Gentlemen,
Today i'm very glad to present you our first «newsletter».
3 or 4 times a year we will write to you, in order to inform you about news and important things on the field of Vibration Control.
Short and sweet we will present what may also be of deep concern to you. Vibration Control is our world with the demand to deliver very high quality at competitve prices.
Our trademarks are industrial-suited sensors and measuring-electronics for many different applications related to Vibration Control on rotating machines.
With our products we fulfill the high demands concerning ATEX versions and SIL 2 (Safet-Integration-Level) as well as the high demands of our satisfied customers, which are using thousands of our sensors in day-to-day operations, appreciating their reliability.
In our first newsletter we will present you our Vibration Control Type 663 – look forward.
Yours sincerely
Tobias BronkalManaging Director HAUBER-Elektronik GmbH
|
|
| |
|
|
| |
| Type 663 |
|
SIL2 / FMEDA classified vibration sensor
- Performance Level, PL-d according to DIN ISO 13849
- Measurement of the vibration speed mm/s (rms)
- Frequency range 1Hz/10Hz…1000Hz
- Output signal 4…20 mA DC and 2x Relay contact
|
The vibration electronics series Typ 663 are developed for safety-related applications in process automation, according to IEC EN 61508/61511.
Small and fine! Inside the stainless steel housing a lot of possibilities are available. The vibration velocity is being measured. Optional from 1 Hz or 10 Hz up to 1000 Hz each. The electronics deliver the effective value of the vibration velocity as a 4…20 mA signal to be connected to a guidance system.
In addition there are 2 relay contacts that generate a pre- and a mainalarm. To avoid fals alarms, for each alarm a delay time can be set.
These compact vibration electronics fulfill the Safet-Integration-level (SIL) 2 and are so the ideal controls in all cases where a high machine safety is required.
HAUBER-Elektronik’s Type 663 was brought to the market as one of the first capable of SIL 2.
Preferably applicable at centrifuges and all other rotating machines, where on excessive swinging values a switch-off is used.
Where explosion protection is required the Type 663 can also be applied with no problem.
ATEX Version
For Zone 1 and 21
II 2G Ex d IIC T4
II 2D Ex tD A21 IP65 T120°C
For Zone 2 and 22
II 3G Ex nC II T4
II 3D Ex tD A22 IP55 T125°C
Visit or web-site to learn more about these extraordinary mearuring electronics.
You wish a consulting or a presentation in your company, so talk to our sales department in Germany.
|
|
| |
|
|
|